Project-specific junction heat-loss calculations

Thermal Bridging Analysis

Get clear PSI-value calculations for suitable construction junctions to support informed fabric specifications and energy modelling.

Clear scope and detailed reportsResponsive project support
Thermal bridging analysis showing temperature contours through a construction junction
Consider building fabric and construction junctions early in the design.

Ψ service

Practical support for your project

Thermal bridges occur where heat flows more readily through a junction than through the surrounding building elements. Project-specific analysis can provide PSI values for suitable details and help the design team understand their effect on calculated performance.
Ψ

What we can provide

  • Calculate project-specific PSI values from supplied junction details
  • Support SAP inputs with appropriate calculation outputs
  • Review continuity of insulation and junction performance
  • Provide clear schedules and assumptions for the project team
RJ

How we work

We agree the details for assessment and review the drawings, dimensions and material build-ups. We clarify assumptions and information gaps, calculate the agreed junctions and provide outputs for the design and energy-assessment team.
Project-specific scope: We will confirm the applicable brief, assumptions, information needed and deliverables before work begins.

A straightforward process

From project information to clear outputs

Thermal bridging temperature contours through a wall and floor junction
Temperature contours help illustrate heat transfer at construction junctions.
STEP 01

Share your plans

Send the drawings and your requirements.
STEP 02

Confirm the scope

We clarify the number of junctions you are having modelled and provide a detailed fee proposal.
STEP 03

Review the design

We assess the information you provide and raise any relevant questions.
STEP 04

Receive your report

We undertake modelling work and issue the agreed outputs, explaining any follow-up information required.

Common questions

Thermal Bridging Analysis FAQs

What junctions can be assessed?

Suitable details may include wall-to-floor, wall-to-roof, openings, corners and other repeated junctions. Suitability depends on the geometry, construction and information provided.

What information is required?

Accurately drawn junction drawings in DXF/DWG format with an accompanying PDF version, material layers and thicknesses, thermal conductivity data where available, and the associated construction specification.

Can PSI values be used in SAP?

Outputs may be used where appropriate to the project and accepted within the applicable assessment process. We can coordinate assumptions and outputs with the SAP assessor. All of our PSI value reports include a ‘construction sign off’ section for the site manager to sign and provide to the SAP assessor at completion of construction works.

Can the analysis help refine details?

We can flag points for the design team to consider, such as insulation continuity or weak points in the design which could be leading to poor results. Design decisions remain with the project team.

Discuss your project with RJ Energy

Send your plans and any planning or building-control notes. We’ll help identify the information needed to scope the work.

Fees and turnaround are confirmed against the project information and agreed brief.

Request a project quote